NOTE: Results presented here are highly dependent on how models are configured in this experiment and may be subject to variable output formatting errors. Results are not intended to indicate the quality of any individual model, but to help participants better understand and improve modelling approaches in different urban environments.

Submitted metadata

Error metrics

flux experiment MAE MBE nSD R 5th 95th RMSE cRMSE AMBE 1-nSD 1-R nSkewness nKurtosis Overlap
SWup baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
SWup detailed 6.00443 3.68475 0.994304 0.98277 0.0379 1.0278 9.38228 0.185192 3.68475 0.00569579 0.01723 0.241222 0.382781 0.0831688
LWup baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
LWup detailed 13.1669 -3.00367 1.2424 0.963537 10.199 26.2057 16.5181 0.386472 3.00367 0.242395 0.0364635 0.160358 0.210862 0.151226
Qle baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
Qle detailed 25.8917 10.5898 1.22102 0.708415 8.5654 52.9392 43.8834 0.872301 10.5898 0.221014 0.291585 0.161396 0.261005 0.185699
Qh baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
Qh detailed 25.4915 10.6225 0.982385 0.919191 10.2801 4.599 38.1139 0.398851 10.6225 0.0176148 0.0808094 0.0202432 0.0564046 0.190884
Qtau baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
Qtau detailed nan nan nan nan nan nan nan nan nan nan nan nan nan nan