NOTE: Results presented here are highly dependent on how models are configured in this experiment and may be subject to variable output formatting errors. Results are not intended to indicate the quality of any individual model, but to help participants better understand and improve modelling approaches in different urban environments.

Submitted metadata

Error metrics

flux experiment MAE MBE nSD R 5th 95th RMSE cRMSE AMBE 1-nSD 1-R nSkewness nKurtosis Overlap
SWup baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
SWup detailed 5.0614 -4.80318 0.836711 0.994134 0.907848 16.3695 7.46752 0.190996 4.80318 0.163289 0.00586604 0.101017 0.494632 0.0926524
LWup baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
LWup detailed 9.03132 6.84144 1.26707 0.96964 1.43648 27.6182 14.9897 0.385048 6.84144 0.267067 0.0303597 1.22056 9.72117 0.111671
Qle baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
Qle detailed 27.9669 20.6761 1.80312 0.797716 3.71146 101.609 51.6246 1.17238 20.6761 0.80312 0.202284 0.139589 0.168919 0.136075
Qh baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
Qh detailed 20.7271 -7.29818 0.716159 0.868417 11.2955 53.9439 32.5025 0.518685 7.29818 0.283841 0.131583 0.155133 0.881699 0.164944
Qtau baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan
Qtau detailed nan nan nan nan nan nan nan nan nan nan nan nan nan nan

Link to variable definitions

subset_SWup_v0-9

CABLE_UK-Swindon_subset_SWup_v0-9.png

out of range: baseline

out of range: detailed

Link to variable definitions