Urban-PLUMBER

A multi-site model evaluation project for urban areas

Phase 2 Phase 1 Download project protocol
Mathew Lipson (UNSW), Sue Grimmond (Reading), Martin Best (Met Office),
with observational and modelling participants.

AU-Preston: CHTESSEL

NOTE: Results presented here are highly dependent on how models are configured in this experiment and may be subject to variable output formatting errors. Results are not intended to indicate the quality of any individual model, but to help participants better understand and improve modelling approaches in different urban environments.

Submitted metadata

Error metrics

flux experiment MAE MBE nSD R 5th 95th RMSE cRMSE AMBE 1-nSD 1-R nSkewness nKurtosis Overlap
SWup baseline 4.20374 2.39741 1.08073 0.995743 0.522681 12.091 6.31439 0.125378 2.39741 0.0807315 0.0042573 0.0857363 0.147575 0.0702675
LWup baseline 8.7697 -2.13268 1.01338 0.965169 5.63217 0.395142 11.3835 0.26603 2.13268 0.0133759 0.0348306 0.0533458 0.0865761 0.0577032
Qle baseline 30.3751 16.518 1.50804 0.717304 8.36094 78.3087 54.0729 1.05392 16.518 0.508038 0.282696 0.249259 0.0596112 0.160789
Qh baseline 27.9029 -8.66174 1.14411 0.912264 24.6328 21.1838 43.9867 0.470666 8.66174 0.144107 0.0877364 0.106677 0.299777 0.184828
Qtau baseline nan nan nan nan nan nan nan nan nan nan nan nan nan nan

Link to variable definitions

Albedo

CHTESSEL_AU-Preston_Albedo.png

Datasheet

CHTESSEL_AU-Preston_Datasheet.png

Distributions

CHTESSEL_AU-Preston_Distributions.png

closure_baseline

CHTESSEL_AU-Preston_closure_baseline.png

subset_Qh

CHTESSEL_AU-Preston_subset_Qh.png

subset_Qle

CHTESSEL_AU-Preston_subset_Qle.png

subset_SWup

CHTESSEL_AU-Preston_subset_SWup.png

out of range: baseline

out of range: detailed

Link to variable definitions